Bongo Technologies · Field resources
Tech & CSR Hub
Install guides, activation steps, troubleshooting and spec sheets for Voice Link V2, Data Link and the Tele-Entry POTS Adapter.
Troubleshooting
Status light: what it meansVoice Link V2 · look through the clear lid, near the bottom edge
| Light | Meaning |
|---|---|
| Solid green | Unit is working. |
| Blinking green | Connecting to the cell network. |
| Red | Firmware issue or processing an update. |
The small light next to the RJ-11 port only shows the port has power. It is not the status light.
Common problems and fixesVoice Link V2
| Problem | What to do |
|---|---|
| No dial tone on the buttset | Check 12V power, the RJ-11 power light, SIM activation, and your crimp. |
| Status light keeps blinking green | Still connecting to the cell network. Check reception and try a better mounting spot. |
| Status light is red | Firmware issue or update in progress. Wait for it to finish, then contact Bongo if it stays red. |
| Choppy or dropped calls | Usually weak signal. Check reception, confirm the run is under 325 ft and the load is 2 REN or less. |
| Emergency phone won't dial out | Enable Ring Down in the Remote Management Platform. It bypasses the number programmed in the emergency phone and automatically dials the number entered in the platform. |
Cell signal (RSRP) levelsRead reception in the Remote Management Platform before mounting
| LTE signal (RSRP) | Rating | Action |
|---|---|---|
| −75 dBm or better | Good | Mount here |
| −75 to −85 dBm | Fair | Test calls thoroughly |
| Worse than −85 dBm | Poor | Relocate the device |
Weak signal? Try higher on the wall, closer to an exterior wall, and away from metal and electrical gear. Basements, telco rooms, machine rooms and metal cabinets weaken signal. The RJ-11 run can reach 325 ft, so mount where signal is best.
Device label: which ID is used whereFront label on every unit
| Field | Use it for |
|---|---|
| Bongo Identifier | Bongo's unique unit ID. Have it ready when contacting support. |
| IMEI | Identifies the cellular communicator. Use it to search for the unit in the Simplifi portal. |
| ICCID | Identifies the embedded SIM. Use it to claim the device in the Bongo Activation Portal. |
Activation
Dealer self-activation: 7 stepsSteps 1–2 in the Bongo Activation Portal · Steps 3–7 in the Simplifi portal
Bongo Activation Portal
- Activate the SIM. From the home screen, click Claim Your Device and follow the steps to activate the SIM and purchase the subscription.
- Update the device nickname. Devices tab → open the unit → pencil icon. Use SITE NAME (ACCOUNT NUMBER). This name appears on billing receipts.
Simplifi portal
- Update the Global Identification. Search the device IMEI, click the blue IMEI, then the pencil to rename the device.
- Disable WiFi. Advanced Information tab → switch off Primary WiFi. Guest WiFi should be off too. This conserves battery power.
- Add a notification email. Advanced Information → pencil on Notification Email → add the address, check Email when the router connection status changes, then Save.
- Update firmware. Router Actions tab → Firmware Update.
- Enable WatchDog. Special Configuration tab → Enable Connection Watchdog, set the timeout to 600 seconds (the minimum the portal accepts), then Save Configuration.
Careful: Factory Reset sits in the same row as Firmware Update. Confirm the button before clicking.
Install
Voice Link V2 install at a glanceActivate and bench test in the office 1–2 days before deployment
- Activate the SIM in the Bongo Activation Portal.
- Test with a buttset. Place a test incoming and outgoing call.
- Locate and mount. Find where the phone line terminates (usually the DMARC), confirm cell signal, and mount the device.
- Test the emergency phone. Place a test call from the emergency phone connected to the device.
Finding the phone line at the DMARCIncludes the live-carrier-line warning
Never connect to a live carrier line. Voice Link V2 supplies its own dial tone. Connecting its RJ-11 port to a pair still tied to the phone company can damage equipment and cause call failures.
- Get the numbers for each emergency line from the building or elevator contractor, and check existing labels at the block.
- Identify each pair. With the line still live, connect a buttset at the block and call a known cell phone. Caller ID confirms which line it is.
- Or trace it. Tone generator at the emergency phone end, inductive probe at the block.
- Label it, for example “Elevator 2, car phone.”
- Isolate the building side. Disconnect the pair from the carrier side (remove bridge clips) before connecting Voice Link V2.
Before cutover: notify the monitoring center that the line is going on test, and coordinate machine room access with the elevator contractor.
Site survey and mountingPower, location and mounting rules
Power outlet
- Standard 120V AC outlet within reach of the 12V power supply cord. No extension cords or power strips.
- Outlet not controlled by a wall switch. Confirm it's live with a tester or multimeter.
- Use a circuit on emergency or generator power when available.
- Label the outlet “Life safety device: do not unplug.”
- Route and secure the cord so it can't be kicked, pulled or pinched.
Mounting
- Indoors, dry, within reach of the outlet, where signal tested best.
- Plywood backboard or wall with suitable screws; anchors in drywall.
- Upright, with the port side accessible and the clear lid visible.
- Clear of electrical panels, transformers and large metal equipment.
- Leave a service loop; use strain relief. Don't pinch wires with staples or ties.
- Label the device with the building, the line it serves, and its Identifier.
RJ-11 termination and pinoutTip in pin 4, ring in pin 3
Viewed with the clip facing down.
Common colors
- Phone wire: green = tip, red = ring
- Cat cable: white/blue = tip, blue = ring
Steps
- Cut square and strip about ½ in of jacket without nicking the wires.
- Tip in pin 4, ring in pin 3 (the center positions).
- Trim evenly so wires reach the front with the jacket under the strain relief.
- Insert clip-side down, confirm each wire reaches the front, crimp firmly.
- Confirm contacts are seated, then check for dial tone with a buttset.
Tip: for a cleaner install, punch the pair down on a surface-mount RJ-11 jack and use a pre-made RJ-11 cord to the device.
Testing and the before-you-leave checklistFive tests, then sign-off
- Power on. Press the power button and wait for a solid green status light.
- Buttset test. At the RJ-11 port, confirm dial tone, then place an outgoing call and receive an incoming call.
- Emergency phone test. Notify the monitoring center, connect the phone, place a call, confirm clear two-way audio.
- Battery test. Briefly unplug 12V power and confirm the unit stays online. Plug it back in.
- Verify remotely. Unit shows online with good reception, and test calls appear in call history.
Give the monitoring center the unit's caller ID number. Find it in the Activation Portal, or place a test call to your cell phone and check the caller ID.
Before you leave
- Device and outlet labeled
- Identifier, IMEI and ICCID recorded
- Monitoring center has the caller ID number
- Test results documented
- Cables secured and lid latched
- Line back in service: monitoring center and building notified
What to bring to every install
- Buttset (lineman's test set)
- Tone generator and inductive probe
- 66/110 punch-down tool
- RJ-11 crimp tool and 6P4C connectors
- Cable stripper and flush cutters
- Outlet tester or multimeter
- Signal meter or phone on AT&T/FirstNet
- Drill, screws, anchors and cable ties
- Labels or a label maker
- Device label info: Identifier, IMEI, ICCID
Products at a glance
Voice Link V2POTS line replacement for elevators and life-safety phones, on FirstNet
- Works with the existing emergency phone, no rewiring
- RJ-11 (FXS) port: runs up to 325 ft, up to 2 REN
- 12V power input with immediate reboot
- Battery backup: 16+ hours, expandable to 32+
- FirstNet voice service, remote device management and 24/7 monitoring included
- Echo cancellation, DTMF tone stabilization, up to 16 kHz HD audio
- Measures line current, voltage and impedance
- Uses: elevators, areas of refuge, two-way communication, pool phones, emergency call boxes
Certifications & compliance
Certified: UL 62368-1, FCC Part 15B Class B. Compliant: ASME A17.1, NFPA 72, UL 2525, UL 864, UL 985, UL 1023, UL 1610, PCI, HIPAA.
Tele-Entry POTS Adapter4G LTE phone line for gate, door and lobby entry systems
- RJ-11 ports for analog tele-entry panels, alarm panels and fax lines
- Up to 3 REN line load, 55 Vrms ring voltage, 500 ft loop length
- Dual SIM slots for failover; activate on AT&T or Verizon, whichever covers the site best
- Certified to UL 62368-1
- Cloud management: check connection and update firmware without a site visit
Plans and hardware pricing: see the dealer sheet below, or sales@bongotechnologies.com.
Data Link4G LTE router
- LTE Cat 4: up to 150 Mbps down / 50 Mbps up
- Dual-band WiFi 5 (802.11 b/g/n/ac), WPA/WPA2/WPA2 Enterprise
- RJ-45 LAN port, USB host port, standard SIM (2FF)
- Power: 120/240 VAC, 10W max · Operating temp −10°C to +40°C
- Carrier approvals: AT&T, FirstNet, T-Mobile, US Cellular, Verizon
Full band list by model is in the spec sheet below.
Documents
Technician Installation Guide
Site survey, DMARC, mounting, RJ-11 termination, testing and troubleshooting. 2 pages.
Open PDF →
Quick Start Guide
Device label, ports, status light and the four-step first install. 1 page.
Open PDF →
Dealer Self-Activation Guide
Seven steps with screenshots: Bongo Activation Portal, then Simplifi. 3 pages.
Open PDF →
Data Link + Voice Link Spec Sheet
Overview, Data Link specs and Voice Link certifications table. 3 pages.
Open PDF →
Tele-Entry POTS Adapter Dealer Sheet
Features, service plan and the copper-vs-Bongo comparison. 1 page.
Open PDF →
Elevator End-User Flyer
“Don't get stuck” flyer for building owners. Contact area is blank for the dealer to fill in. 1 page.
Open PDF →
Videos
Training videos are coming soon.
No matches. Try another word, or call 920-461-2081.